Open-path multi-pass cell helps measure atmospheric H2O and CO2 fluxes online

Photograph of the TDLAS sensor and schematic of the open-path TDLAS system used for measuring atmospheric H2O and CO2 concentrations. Credit: Gu Mingsi
× close
Photograph of the TDLAS sensor and schematic of the open-path TDLAS system used for measuring atmospheric H2O and CO2 concentrations. Credit: Gu Mingsi

According to a study published in Optics Express, a research team from the Hefei Institutes of Physical Science of the Chinese Academy of Sciences proposed a new design for online measurement of atmospheric H2O and CO2 fluxes.

"We designed an open-path and anti-pollution multi-pass cell," said Prof. Gao Xiaoming, who led the team, "and applied it on tunable diode laser absorption spectroscopy sensor (TDLAS)."

The new gas analysis instrument exhibited good consistency with commercial instruments, and its accuracy was comparable.

One of the most important ways to reduce is to store carbon in soil and vegetation. Scientists suggest using turbulent eddies generated by air flow to measure .

Photograph of the installation and comparison of the field measurements obtained using TDLAS and LI-7500 for 24 h. Credit: Gu Mingsi
× close
Photograph of the installation and comparison of the field measurements obtained using TDLAS and LI-7500 for 24 h. Credit: Gu Mingsi
Comparison of (a) CO2 flux and (b) H2O flux for approximately a month. Credit: Gu Mingsi
× close
Comparison of (a) CO2 flux and (b) H2O flux for approximately a month. Credit: Gu Mingsi

Equipment based on tunable laser absorption spectroscopy combined with eddy covariance technology has many advantages including , high precision, and fast response. There are two gas path methods for measuring gas fluxes: open-path and closed path. However, the traditional open-path multi-pass cell is unsuitable because its optical path is exposed to air, which causes the coating layer of the lens to be corroded in the atmosphere.

Different from traditional multi-pass cells, this novel anti-pollution open-path multi-pass cell is mainly composed of two plano-convex mirrors coated on a convex surface.

"It's coated on the reverse side," said Gao. "The design does not allow a direct contact between the coating layer of the lens and air, that's why it has the anti-pollution effect."

This design effectively avoids the pollution and corrosion of the lens film layer by the external environment. When it is applied to the flux monitoring equipment of atmospheric greenhouse gases CO2 and H2O, the long-term stability and durability of the open-path system is improved.

Researchers setting up self-made instrument for comparative observation experiment. Credit: by Gu Mingsi
× close
Researchers setting up self-made instrument for comparative observation experiment. Credit: by Gu Mingsi

The design was further proved in a field comparative observation experiment on the CO2 and H2O fluxes of the wheat seasonal farmland ecosystem. The results were in good agreement with those achieved using the non-dispersive infrared-based commercial instrument.

"We see strong application prospects for measurements in any ecosystem," said Gao.

More information: Mingsi Gu et al, Open-path anti-pollution multi-pass cell-based TDLAS sensor for the online measurement of atmospheric H2O and CO2 fluxes, Optics Express (2022). DOI: 10.1364/OE.474070

Journal information: Optics Express